This has been documented in Knowledge Base article Q5450. Instead the CitectSCADA Web Server must be uninstalled to remove both the base product and Service Pack, and then the base product may be reinstalled. #Citect process analyst pen assinment windows 7WebServer Service Pack cannot be independently uninstalled on Windows Vista and Windows 7 On Microsoft Vista and Windows 7, the Web Server Service Pack cannot be uninstalled independently from the base application. #Citect process analyst pen assinment updateCustomers experiencing this issue should do an Update Pages (in Graphics Builder→Tools→Update Pages) on any affected projects. "Incorrect arguments" compile error after uninstalling service pack After uninstalling service pack 4 (back to the release version) all projects that use the CSV_Include project (including the CSV_Example and Facilities projects) give a compile error indicating "incorrect arguments". Known Issues: This Service Pack contains the known issues described below. #Citect process analyst pen assinment upgradeThis service pack applies to three of the products shipped with CitectSCADA version 7.10: a)Ĭ) CitectSCADA Internet Display Client Separate service pack installers have been created for each of these products, allowing you to choose which products you wish to upgrade to Service Pack 4, depending on your requirements. Note: For general information about service packs, see Knowledge Base article Q2181. #Citect process analyst pen assinment installThis Service Pack accumulates all of the updates included in V7.10 Service Packs 1, 2, and 3, so it is not necessary to install the older Service Packs first. SCADA Global Support recommends V7.10 users apply the Service Pack as soon as practically possible. Hot Fixes Customers who have hot fixes installed should check the release notes to ensure the applicable fix is included in V7.10 Service Pack 4 - please contact SCADA Global Support if in any doubt. Please contact Schneider Electric SCADA Global Support if you require assistance or advice regarding this procedure. Important Note: Please do not restore your old backed-up Tagdriv.ini file. If you have a modified Tagdriv.ini file, you will need to edit the new Tagdriv.ini file to get your changes back. The recommended upgrade procedure is to backup Tagdriv.ini before installing V7.10 Service Pack 4. Tagdriv.ini file change The Tagdriv.ini file was necessarily modified in V7.10 Service Pack 4. Important Note: Please do not restore your old backed-up m file or you will get errors in your project. If you have a modified m file, you will need to edit the new m file to get your changes back. The recommended upgrade procedure is to backup all project files (including the m file) before installing V7.10 Service Pack 4. This caused issues for some users who had modified their m file previously. Lastly, restore your projects and recompile to run on Windows 7.Ĭm file change The m file was necessarily modified in V7.10 Service Pack 2. After installing the product, please install V7.10 Service Pack 4 to ensure Windows 7 compatibility. #Citect process analyst pen assinment driversUpdated drivers stamped for Windows 7 are available for download from our DriverWeb website. Ignore any warnings that drivers may not be compatible with Windows 7 - the majority of the drivers have been tested and will function correctly. To run on Windows 7, please install your SCADA product using your product DVD. Windows 7 Compatibility The application of the V7.10 Service Pack 4 will allow users to run the product on the Windows 7 operating system. Customers should also do an Update Pages (in Graphics Builder→Tools→Update Pages) on any projects using CSV_Include templates. Ensure that the Incremental Compile menu option (in Project Editor→Tools→Options) is not checked, or set INCREMENTALCOMPILE=0. To force an upgrade, edit the Citect.ini file and set UPGRADE=1. Failure to do so will result in conflicting database size messages. Important: All projects must be upgraded and recompiled after installing this Service Pack. Important: As per recommended practice, all projects should be backed up prior to commencing the Service Pack installation. CitectSCADA 7.10 Release Notes for Service Pack 4 The V7.10 Service Pack 4 includes several product updates and enhancements, providing improvements in stability, performance and functionality.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |